Arming the System
To arm your ITI security system (e.g., Concord, Simon):
- Stay Mode: Press [CODE] + [3] or press [STAY] button (if enabled). Arms perimeter zones; interior bypassed.
- Away Mode: Press [CODE] + [2] or press [AWAY] button (if enabled). Arms all zones (perimeter and interior).
The "Armed" light turns on, and an exit delay (typically 30-60 seconds) begins. Exit before it ends; the keypad beeps rapidly in the last 10 seconds.
|
Disarming the System
To disarm:
- Enter your 4-digit code + [1] (OFF) or press [DISARM] button (if enabled) followed by your code.
- The "Armed" light turns off, and entry tones stop.
- If "Armed" flashes upon entry, an alarm occurred—exit and contact your alarm company.
Disarm within the entry delay (e.g., 30 seconds) to avoid an alarm.
|
Arming Modes Breakdown
- Stay: Perimeter protection only; interior sensors off. Ideal for occupants staying inside.
- Away: Full protection; all sensors active. Use when the premises are unoccupied.
Keypad may announce "System Armed Stay" or "System Armed Away" (e.g., Concord with voice module).
|
Quick Arm Instructions with Dedicated Buttons
If enabled, use these dedicated keypad buttons for quick arming (no code required unless noted):
- [STAY]: Press [STAY] to arm in Stay mode instantly. Perimeter zones armed, interior bypassed.
- [AWAY]: Press [AWAY] to arm in Away mode. All zones armed; exit delay starts.
- [QUICK EXIT]: Press [QUICK EXIT] while armed to open an exit zone (e.g., door) for 2 minutes without disarming.
- [DISARM]: Press [DISARM] + [CODE] to disarm quickly (code required).
Verify with your installer if these buttons are active (common on Concord, Simon XT keypads).
|
Bypassing Zones
To bypass a zone while disarmed:
- Press [BYPASS] or [*][6], enter your code, then the 2-digit zone number (e.g., [0][5] for zone 5).
- Press [#]. "Bypass" light illuminates, and the zone is skipped when armed.
- Bypasses reset upon disarming.
Caution: Bypassing reduces security, especially entry/exit zones in Away mode.
|
Enabling Chime
To toggle chime (alerts for zone openings when disarmed):
- Press [*][7] or hold [CHIME] (if available).
- "Chime On" displays or a tone confirms; repeat to turn off.
- Sounds when monitored zones open.
Useful for tracking activity without arming.
|
Changing Codes
To change a user code (master code required):
- Press [*][5], enter [master code].
- Enter 2-digit user number (e.g., [0][2] for user 2).
- Enter new 4-digit code, then [#].
- To delete, press [*][5][master code][user number][*][#].
Test new codes to confirm functionality.
|
Reviewing Faults
To check faults:
- If "Ready" light is off, press [STATUS] or [*] to view faulted zones (e.g., "Zone 05 Open").
- Scroll with [A] or [B] keys (if available, e.g., Concord) or note zone numbers.
- Resolve (e.g., close door) or bypass, then [#].
Ensures all zones are secure before arming.
|
Bypassing Effectiveness & Cautions
Bypassing allows arming despite faults but compromises security:
- Bypassed zones are unprotected, increasing vulnerability.
- Avoid bypassing entry/exit zones in Away mode, as it negates perimeter protection when absent.
- Use temporarily; contact your installer for permanent fixes.
- Test monthly: Arm, trigger a zone, disarm (notify monitoring first).
|