Alarm Panel Procedures Quick Reference

Click on Panel Name for extended info

Panel Name Arm/Disarm Reset Bypass
Acron
  • Arm: Enter code then hit #
  • Disarm: Enter code then hit #
Reset: Press # Bypass: Enter code, select zone, press #
Ademco
  • Arm: Code + 2 for Away
  • Disarm: Code + 1 for Off
  • Reset: Code + 1
  • Press * for STAT
Bypass: Code + 6 + 2-digit zone
Bosch
  • Arm: Code + 2 (Away) or 3 (Stay) or [AWAY]/[STAY]
  • Disarm: Code + 1 or [OFF]
  • Quick Arm: [AWAY] or [STAY] (newer)
Reset: [4] + [ENTER] or [RESET] Bypass: [0] + zone + [ENTER] or [BYPASS] + zone
Caddx
  • Arm: Enter code
  • Disarm: Enter code
Reset: Press # Bypass: Press * + zone + *
DMP
  • Arm: Enter code
  • Disarm: Enter code, press CMD
  • Stay Mode: Code, scroll to Home/Sleep/Away
Reset: Enter code, scroll to Alarm Silence or Sensor Reset Bypass: Use CMD key to display bypass, select zone
DSC
  • Arm: Enter code
  • Disarm: Enter code
  • Quick Arm: Press * + 0
  • Reset Fire: Press *72
  • Silence: Press #, then reset
Bypass: Enter function menu (*), press 8, select zone
GE
  • Arm: Code + 2 (Away) or 3 (Stay)
  • Disarm: Code + 1
Reset: Press * + 7 Bypass: Press * + 6 + zone + #
ITI
  • Arm: Code + 2 (Away) or 3 (Stay)
  • Disarm: Code + 1
Reset: Press * + 7 Bypass: Press * + 6 + zone + #
Moose
  • Arm: 1 + Code
  • Disarm: 1 + Code
  • Force Arm: Enter code, press "Override"
Reset: Press * three times or enter code + * Bypass: Press Bypass + Zone
Napco
  • Arm: Code + On
  • Disarm: Code + Off
  • Quick Arm: Press On/Off button
Reset: Press Reset Button Bypass: Code + Bypass + Zone
Northern
  • Arm: Code + 9
  • Disarm: Code + 0
Reset: Silence: Mute + Code Bypass: Zone + BYPS + Code
Radionics
  • Arm: Enter code
  • Disarm: Enter code
  • Force Arm: Hold last digit until "ARMED"
Reset: Command 4 (Burg) or Command 47 (Fire) Bypass: Arm system, press COMMAND + Zone

Bosch Security System Detailed Instructions

Arming the System:

Disarming: Enter [CODE] + [1] + [ENTER] or press [OFF] (newer) or tap "Off" (touch screen) + [CODE]. "Armed" light off, tones stop. Disarm within entry delay.

Quick Arm: If enabled, press [2] (Away) or [3] (Stay) (older); [AWAY] or [STAY] (newer); or tap "Away"/"Stay" (touch screen). Code needed to disarm.

Bypassing Zones: Press [0] + zone (e.g., [5]) + [ENTER] (older) or [BYPASS] + 2-3 digit zone (e.g., [0][0][5]) + [ENTER] or tap "Bypass" + zone (touch screen). "Bypass" light on; resets on disarm.

Enabling Chime: Press [7] + [ENTER] (older) or [CHIME] (newer) or tap "Chime" (touch screen). "Chime On" displays; repeat to turn off. Alerts for zone openings.

Changing Codes: Press [5] + [ENTER] + [master code] + user number (e.g., [0][2]) + new code + [ENTER] (older) or [MENU] + [master code] + 3-digit user (e.g., [0][0][2]) + new code + [ENTER] (newer/touch screen). Test new code.

Reviewing Faults: If "Ready" off, press [2] + [ENTER] (older) or [MENU] > "Status" (newer) or tap "Status" (touch screen); view faults (e.g., "Zone 05 Faulted"). Resolve or bypass, press [ESC].

Caution: Avoid bypassing entry/exit zones in Away mode; reduces security. Test monthly.

GE Security System Detailed Instructions

Arming the System:

Disarming: Enter [CODE] + [1]. "Armed" light off, entry tones stop. Disarm within delay.

Quick Arm: If enabled, press [2] (Away) or [3] (Stay); code required to disarm.

Bypassing Zones: Press [*][6] + [CODE] + 2-digit zone (e.g., [0][5]) + [#]. "Bypass" light on; clears on disarm.

Enabling Chime: Press [*][7]. "Chime On" shows; repeat to turn off. Sounds for zone activity.

Changing Codes: Press [*][5] + [master code] + 2-digit user (e.g., [0][2]) + new 4-digit code + [#]. Verify new code.

Reviewing Faults: If "Ready" off, press [*]; view faults (e.g., "Zone 05 Open"). Fix or bypass, press [#].

Caution: Bypassing entry/exit zones in Away mode weakens security. Test monthly.

ITI Security System Detailed Instructions

Arming the System:

Disarming: Enter [CODE] + [1]. "Armed" light off, tones stop. Disarm within entry delay.

Quick Arm: If enabled, press [2] (Away) or [3] (Stay); code needed to disarm.

Bypassing Zones: Press [*][6] + [CODE] + 2-digit zone (e.g., [0][5]) + [#]. "Bypass" light on; resets on disarm.

Enabling Chime: Press [*][7]. "Chime On" displays; repeat to turn off. Alerts for zone openings.

Changing Codes: Press [*][5] + [master code] + 2-digit user (e.g., [0][2]) + new 4-digit code + [#]. Test new code.

Reviewing Faults: If "Ready" off, press [STATUS] or [*]; view faults (e.g., "Zone 05 Open"). Resolve or bypass, press [#].

Caution: Avoid bypassing entry/exit zones in Away mode; reduces security. Test monthly.

Radionics Security System Detailed Instructions

Arming the System:

Disarming: Enter [CODE] + [ENT]. "Armed" light off, tones stop. Disarm within entry delay.

Quick Arm: If enabled, press [COMMAND] + [1] (Away) or [COMMAND] + [2] (Stay); code needed to disarm.

Bypassing Zones: Press [CODE] + [0] + zone number (e.g., [5]) + [ENT]. "Bypass" light on; resets on disarm.

Enabling Chime: Press [COMMAND] + [6]. "Chime On" displays; repeat to turn off. Alerts for zone openings.

Changing Codes: Press [COMMAND] + [5] + [master code] + user number (e.g., [2]) + new 4-digit code twice + [ENT]. Test new code.

Reviewing Faults: If "Ready" off, press [*]; view faults (e.g., "Zone 05 Open"). Resolve or bypass, press [ENT].

Caution: Avoid bypassing entry/exit zones in Away mode; reduces security. Test monthly.